- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 1Motor rotation is stalled
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 2Hall sensing fault
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 3Motor temperature is above the operating limit
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 4Drive power stage is overheating
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 5Drive power stage reached its temperature warning level
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 6U-phase current tripped hardware protection
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 7V-phase current tripped hardware protection
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 8W-phase current tripped hardware protection
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 9Hardware detected excessive bus voltage
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 10Hardware detected excessive bus current
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 11Controller reports a hardware fault
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 12Battery voltage is above range
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 13Battery voltage is below range
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 14Motor reached its temperature warning level
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 15Battery charge is low
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 16DC bus voltage is too high
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 17DC bus voltage is too low
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 18DC bus current is too high
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 19Torque current Iq remained at its limit too long
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 20Throttle was away from neutral at power-up
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 21Tiller interlock signal disappeared during travel
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 22Throttle request preceded tiller positioning
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 23Emergency reverse input fault
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 24Direction switch signal fault
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 25Travel speed exceeded its limit
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 26EEPROM memory fault
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 27Travel requested during charging
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 28Current measurement circuit fault
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 29Deceleration exceeded its time limit
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 30Emergency reverse during throttle input triggered a stop
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 31Motor temperature sensing circuit is open
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 32Motor temperature sensing circuit is shorted
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 33IGBT temperature sensing circuit is open
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 34IGBT temperature sensing circuit is shorted
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 35Software detected high U-phase current
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 36Software detected high V-phase current
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 37Software detected high W-phase current
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 38Relay circuit is open
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 39Relay circuit is shorted
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 40Mechanical brake circuit is open
- Hangcha CBD20-A3MA / CBD20-A3MA-IFault code 41Mechanical brake circuit is shorted
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 1,1 (1 flash, then 1 flash)Temperature protection triggered; load and ambient conditions are possible factors
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 1,2 (1 flash, then 2 flashes)Throttle input fault involving the wiper signal or throttle type
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 1,3 (1 flash, then 3 flashes)Battery supply undervoltage; the manual lists a level below 17 V
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 1,4 (1 flash, then 4 flashes)Battery supply overvoltage; the manual lists a level above 31 V
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 1,5 (1 flash, then 5 flashes)Emergency reverse switch was active before key-on
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 2,1 (2 flashes, then 1 flash)Main contactor failed to release; contacts or drive may be involved
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 2,2 (2 flashes, then 2 flashes)Main contactor drive circuit is open
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 2,3 (2 flashes, then 3 flashes)Brake release fault; an open coil is among the listed causes
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 2,5 (2 flashes, then 5 flashes)Controller precharge failed
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 3,1 (3 flashes, then 1 flash)Brake engagement fault; a shorted coil is among the listed causes
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 3,2 (3 flashes, then 2 flashes)Excess current detected; a shorted motor is a possible cause
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 3,3 (3 flashes, then 3 flashes)Controller could not read or write EEPROM
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 3,4 (3 flashes, then 4 flashes)Battery disconnected or main supply connection poor
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 3,5 (3 flashes, then 5 flashes)Lift switch was active before key-on
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 4,1 (4 flashes, then 1 flash)Direction input preceded the interlock
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 4,2 (4 flashes, then 2 flashes)Internal 15 V rail measured above 18 V or below 10 V
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 4,3 (4 flashes, then 3 flashes)Power switching fault on motor bridge leg M1
- Hangcha CBD15-A3MJ / CBD15-A3MJ-D / CBD15-A3MJ-I / CBD15-A3MJ-IDLED flash code 4,4 (4 flashes, then 4 flashes)Power switching fault on motor bridge leg M2
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 1Lamp pattern 1.1Controller temperature above 100 °C or below −40 °C
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 2Lamp pattern 1.2Motor temperature is elevated
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 3Lamp pattern 1.3Throttle or tiller analog input fault
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 4Lamp pattern 1.4Battery voltage exceeded 35 V
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 5Lamp pattern 1.5Battery voltage fell below 17 V
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 6Lamp pattern 1.6Controller current exceeded its protection limit
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 7Lamp pattern 2.1Precharge circuit fault
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 8Lamp pattern 2.1Precharge took too long
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 9Lamp pattern 2.2Main contactor contacts stuck
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 10Lamp pattern 2.3Open main contactor drive circuit
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 11Lamp pattern 2.4Motor connection issue at M1 or M2
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 12Lamp pattern 2.5Brake release fault associated with a shorted drive circuit
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 13Lamp pattern 2.6Brake engagement fault associated with an open drive circuit
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 14Lamp pattern 3.1Internal controller hardware fault
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 15Lamp pattern 3.2Parameter read or write failed in EEPROM
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 16Lamp pattern 3.3Battery charge below the configured limit
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 17Lamp pattern 3.4Emergency reverse input timing or logic fault
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 18Lamp pattern 3.5Lift switch operation fault
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 19Lamp pattern 3.6Battery power connection fault
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 20Lamp pattern 4.1Internal 15 V rail above 18 V or below 12 V
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 21Lamp pattern 4.2Interlock switch startup sequence fault
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 22Lamp pattern 4.3M1 bridge fault involving the power stage or motor wiring
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 23Lamp pattern 4.4M2 bridge fault involving the power stage or motor wiring
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 24Lamp pattern 4.5Communication failed on the CAN bus
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 25Lamp pattern 4.6Lift relay release fault associated with a drive circuit short
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 26Lamp pattern 5.1Lift relay engagement fault, possibly an open coil
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 27Lamp pattern 5.2Lowering relay release fault associated with a drive circuit short
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 28Lamp pattern 5.3Lowering relay engagement fault, possibly an open coil
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 29Lamp pattern 5.4Upright travel switch logic fault
- Hangcha CDD12-A2MJ2 / CDD15-A2MJ2 / CTD12-A2MJ2 / CTD15-A2MJ2Fault code 30Interlock opened during travel, classified as a temporary fault
- EP Equipment EPT20-15ETLED flash code 1,1 (1 flash, then 1 flash)Temperature outside the control range caused output reduction
- EP Equipment EPT20-15ETLED flash code 1,2 (1 flash, then 2 flashes)Throttle potentiometer low or wiper input outside range
- EP Equipment EPT20-15ETLED flash code 1,3 (1 flash, then 3 flashes)Speed-limit potentiometer wiper signal outside range
- EP Equipment EPT20-15ETLED flash code 1,4 (1 flash, then 4 flashes)Low battery supply; the manual lists voltage below 17 V or a poor supply connection
- EP Equipment EPT20-15ETLED flash code 1,5 (1 flash, then 5 flashes)Supply overvoltage; the manual lists battery voltage above 31 V
- EP Equipment EPT20-15ETLED flash code 2,1 (2 flashes, then 1 flash)Main contactor driver failed open
- EP Equipment EPT20-15ETLED flash code 2,3 (2 flashes, then 3 flashes)Main contactor fault involving the contacts or drive circuit
- EP Equipment EPT20-15ETLED flash code 2,4 (2 flashes, then 4 flashes)Main contactor driver remains on
- EP Equipment EPT20-15ETLED flash code 3,1 (3 flashes, then 1 flash)High pedal disable condition persisted for over ten seconds
- EP Equipment EPT20-15ETLED flash code 3,2 (3 flashes, then 2 flashes)Brake on-state fault; driver short or open coil possible
- EP Equipment EPT20-15ETLED flash code 3,3 (3 flashes, then 3 flashes)Precharge failed, possibly in the precharge circuit or power stage
- EP Equipment EPT20-15ETLED flash code 3,4 (3 flashes, then 4 flashes)Brake off-state fault; open driver or shorted coil possible
- EP Equipment EPT20-15ETLED flash code 3,5 (3 flashes, then 5 flashes)High pedal disable interlock triggered, possibly due to throttle input timing
- EP Equipment EPT20-15ETLED flash code 4,1 (4 flashes, then 1 flash)Current reading outside range, possibly due to a motor or wiring short
- EP Equipment EPT20-15ETLED flash code 4,2 (4 flashes, then 2 flashes)Hardware protection detected motor voltage inconsistent with throttle demand
- EP Equipment EPT20-15ETLED flash code 4,3 (4 flashes, then 3 flashes)Stored EEPROM data failed its checksum
- EP Equipment EPT20-15ETLED flash code 4,5 (4 flashes, then 5 flashes)Battery connection missing, possibly due to poor terminal contact
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 42Controller hardware fault
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 41Current measurement fault
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 33Precharge failed
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 32Brake on-state fault
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 45Battery disconnection detected
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 43Invalid controller parameters
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 34Brake off-state fault
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 21Main relay failed to close
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 31Wiring fault reported
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 23Main driver circuit fault
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 24Main relay contacts stuck closed
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 12Throttle input fault
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 35High pedal disable interlock active
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 22Emergency reverse sequence fault
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 15Output reduced due to high voltage
- Xilin (Ningbo Ruyi) CBD15W-IILiFault code 14Output reduced due to low voltage
- Noblelift EPT15LED flash code 1,1 (1 flash, then 1 flash)Controller output is reduced at excessive or insufficient temperature
- Noblelift EPT15LED flash code 1,2 (1 flash, then 2 flashes)Throttle potentiometer low or wiper input is outside range
- Noblelift EPT15LED flash code 1,3 (1 flash, then 3 flashes)Speed-limit potentiometer wiper reading is outside range
- Noblelift EPT15LED flash code 1,4 (1 flash, then 4 flashes)Supply undervoltage, possibly involving the battery or controller connections
- Noblelift EPT15LED flash code 1,5 (1 flash, then 5 flashes)Supply overvoltage; listed conditions include a battery reading above 31 V
- Noblelift EPT15LED flash code 2,1 (2 flashes, then 1 flash)Main contactor driver failed open
- Noblelift EPT15LED flash code 2,3 (2 flashes, then 3 flashes)Main contactor or drive fault, potentially involving welded contacts
- Noblelift EPT15LED flash code 2,4 (2 flashes, then 4 flashes)Main contactor driver remains on
- Noblelift EPT15LED flash code 3,1 (3 flashes, then 1 flash)High pedal disable condition persisted for over ten seconds
- Noblelift EPT15LED flash code 3,2 (3 flashes, then 2 flashes)Brake on-state fault; possible driver short or open coil
- Noblelift EPT15LED flash code 3,3 (3 flashes, then 3 flashes)Precharge failed, possibly in the charging circuit or power stage
- Noblelift EPT15LED flash code 3,4 (3 flashes, then 4 flashes)Brake off-state fault; possible open driver or shorted coil
- Noblelift EPT15LED flash code 3,5 (3 flashes, then 5 flashes)High pedal disable interlock is active
- Noblelift EPT15LED flash code 4,1 (4 flashes, then 1 flash)Measured current is outside the sensing range
- Noblelift EPT15LED flash code 4,2 (4 flashes, then 2 flashes)Hardware protection detected motor voltage inconsistent with demand
- Noblelift EPT15LED flash code 4,3 (4 flashes, then 3 flashes)EEPROM data failed its checksum
- Noblelift EPT15LED flash code 4,5 (4 flashes, then 5 flashes)Battery connection is missing or intermittent at the terminals
- XCMG XCS4531KFault code P054401Electrical fault in bank 1 exhaust temperature sensor 1 or its circuit
- XCMG XCS4531KFault code P054411Bank 1 exhaust temperature sensor 1 circuit shorted to ground
- XCMG XCS4531KFault code P054415Bank 1 exhaust temperature sensor 1 circuit shorted to supply or open
- XCMG XCS4531KFault code P10AD11Reductant pump A low-side control circuit shorted to ground
- XCMG XCS4531KFault code P10AD12Reductant pump A low-side control circuit shorted to supply
- XCMG XCS4531KFault code P10AD13Reductant pump A low-side control circuit is open
- XCMG XCS4531KFault code P10CE97No reductant return flow detected; the system reports a restriction
- XCMG XCS4531KFault code P202D7AAftertreatment reagent pressure fault indicating leakage or seal failure
- XCMG XCS4531KFault code P203A01Electrical fault in reductant level sensor A or its circuit
- XCMG XCS4531KFault code P203A12Reductant level sensor A circuit shorted to supply
- XCMG XCS4531KFault code P203A13Reductant level sensor A circuit is open
- XCMG XCS4531KFault code P204712Bank 1 reductant injection valve 1 control circuit shorted to supply
- XCMG XCS4531KFault code P204713Bank 1 reductant injection valve 1 control circuit is open
- XCMG XCS4531KFault code P204773Reductant injection valve reported stuck closed, preventing commanded dosing
- XCMG XCS4531KFault code P204A11Reductant pressure sensor circuit shorted to ground
- XCMG XCS4531KFault code P204A13Reductant pressure sensor circuit is open
- Jungheinrich EJC 112zFault code E-0914Tiller was outside its braking zone at power-up
- Jungheinrich EJC 112zFault code E-1901At switch-on the travel switch was off neutral or the slow-travel button was pressed
- Jungheinrich EJC 112zFault code E-1914Collision safety switch was pressed at power-up
- Jungheinrich EJC 112zFault code E-2951Lift or lower button was active at power-up
- Jungheinrich EJC 112zFault code E-2124Implausible mast switch signal can prevent lifting
- Linde H25D / H30D / H35DFault code X201Engine oil level is low; the display also shows a double downward arrow
- Linde H25D / H30D / H35DFault code X202Engine lubrication pressure is too low
- Linde H25D / H30D / H35DFault code X204Engine temperature reached the alarm threshold
- Linde H25D / H30D / H35DFault code X205Hydraulic oil temperature reached the alarm threshold
- Curtis 1220Fault code 12Excess current shuts down steering and requests a traction stop
- Curtis 1220Fault code 13Current measurement fault shuts down steering
- Curtis 1220Fault code 14Precharge failure shuts down steering
- Curtis 1220Fault code 15Steering controller reports a severe low-temperature warning
- Curtis 1220Fault code 16Severe controller overheating triggers a warning then steering shutdown
- Curtis 1220Fault code 17Severe supply undervoltage shuts down steering
- Curtis 1220Fault code 18Severe overvoltage, potentially involving the battery connection during regeneration
- Curtis 1220Fault code 21Steering motor heat causes current limiting
- Curtis 1220Fault code 22Controller heat triggers a traction speed reduction
- Curtis 1220Fault code 23Motor polarity or position feedback direction reversed
- Curtis 1220Fault code 245 V supply fault, possibly due to an overloaded output
- Curtis 1220Fault code 31Internal relay drive fault
- Curtis 1220Fault code 32Internal relay contacts stuck closed
- Curtis 1220Fault code 33Internal relay failed to close on command
- Curtis 1220Fault code 34Controller hardware fault shuts down steering
- Curtis 1230LED flash code 1,2 (1 flash, then 2 flashes)Motor connections or encoder feedback faulty
- Curtis 1230LED flash code 1,3 (1 flash, then 3 flashes)Excessive motor current
- Curtis 1230LED flash code 1,4 (1 flash, then 4 flashes)Static return to off sequence fault
- Curtis 1230LED flash code 1,5 (1 flash, then 5 flashes)Motor rotation stalled
- Curtis 1230LED flash code 2,1 (2 flashes, then 1 flash)Throttle wiper signal above range
- Curtis 1230LED flash code 2,2 (2 flashes, then 2 flashes)Emergency reverse circuit wiring fault
- Curtis 1230LED flash code 2,3 (2 flashes, then 3 flashes)Hour-meter timer expired or high pedal disable sequence fault
- Curtis 1230LED flash code 2,4 (2 flashes, then 4 flashes)Throttle wiper signal above range
- Curtis 1230LED flash code 3,1 (3 flashes, then 1 flash)Tiller multiplexing module fault
- Curtis 1230LED flash code 3,2 (3 flashes, then 2 flashes)Fault in the main contactor
- Curtis 1230LED flash code 3,3 (3 flashes, then 3 flashes)Brake system fault
- Curtis 1230LED flash code 4,1 (4 flashes, then 1 flash)Battery voltage below range
- Curtis 1230LED flash code 4,2 (4 flashes, then 2 flashes)Battery voltage above range
- Curtis 1230LED flash code 4,3 (4 flashes, then 3 flashes)Controller temperature outside operating range
- Curtis 1230LED flash code 4,4 (4 flashes, then 4 flashes)Anti-tiedown interlock fault
- Curtis 1230LED flash code 5,1 (5 flashes, then 1 flash)Internal controller failure
- Curtis 1230LED flash code 5,2 (5 flashes, then 2 flashes)Internal controller failure
- Curtis 1230LED flash code 5,3 (5 flashes, then 3 flashes)Internal controller failure